AW1303 series split single end mechanical seal for pumps
Structural characteristics
●It adopts single-end face, unbalanced design, split structure (seal chamber and seal assembly are separated), metal parts are made of stainless steel, and the whole is connected to the pump body through flanges. On-site assembly is required during installation.
●The typical configuration of friction pairs is carbide against graphite (general wear resistance) or silicon carbide against silicon carbide (strong wear resistance and corrosion resistance). The auxiliary sealing ring can be made of nitrile rubber (conventional medium) or fluororubber (strong corrosion, high temperature medium).
●The built-in spring provides pre-tightening force and the transmission sleeve is used for transmission. It has high requirements on the coaxiality of the equipment. The compression amount of the sealing component needs to be adjusted on site to ensure the sealing surface fits.
Working parameters
●Pressure: ≤2.0MPa
●Temperature: -20℃~180℃ (fluorine rubber sealing ring can be extended to 200℃)
●Linear speed: ≤20m/s
●Shaft diameter: φ20mm~φ100mm (specific model needs to match the shaft diameter)
●Axial movement: ±0.5mm
Applicable media
General media such as water, oil, organic solvents, weak acid and weak alkali solutions; sewage and chemical liquids containing a small amount of particles (need to be used with silicon carbide to silicon carbide friction pairs); some corrosion-resistant models are suitable for weakly corrosive acid and alkali media.
Application Areas
●Pumps: shaft seals for rotating equipment such as centrifugal pumps, chemical process pumps, clean water pumps, and sewage pumps.
●Industry coverage: chemical industry, municipal water supply, machinery manufacturing, sewage treatment and other fields.
Special Instructions
●During installation, the coaxiality between the sealing chamber and the shaft must be strictly checked (error ≤ 0.05mm), and the surface roughness of the shaft diameter must reach Ra ≤ 3.2μm.
●The bulk structure requires precise on-site adjustment of the sealing component compression to ensure uniform fit of the sealing surface; for working conditions containing particulate media, silicon carbide-to-silicon carbide friction pairs must be used to avoid excessive wear of the sealing surface.
●This series is a customized model. When selecting, you need to check the shaft diameter, seal chamber installation dimensions and media characteristics to ensure that it is fully compatible with the equipment.