In-depth Analysis and Solutions to Water Leakage Problems of Water Pump Mechanical Seals
Water pump mechanical seal leakage is a common issue in water pump failures, so mechanical seals are regarded as critical vulnerable components among water pump parts.
During selection, it is essential to ensure that the material of the mechanical seal is compatible with the liquid medium being transported by the user.
Typically, water pumps are factory-equipped with mechanical seals made of fluororubber or nitrile rubber.
However, for highly corrosive media, mechanical seals made of PTFE (polytetrafluoroethylene) should be selected to ensure durability.

Causes and Solutions for Water Pump Mechanical Seal Leakage

1.1 Material Selection Compatibility Issues
The selection of mechanical seal materials is crucial because the mechanical seal material should be compatible with the liquid medium to avoid leakage caused by improper material selection.
1.2 Leakage Due to Wear
1.2.1 Factors Causing Wear on the Planes of Rotating and Stationary Rings
One of the possible causes of water leakage at the mechanical seal is the wear on the planes of the rotating and stationary rings of the mechanical seal. This wear may be caused by the following six factors:
1.2.2 Over-tight Installation
If severe scorching is observed on the planes of the rotating and stationary rings of the mechanical seal, with the planes turning black and accompanied by deep marks, and the sealing rubber becoming hard and losing elasticity, this is usually due to over-tight installation. The solution is to adjust the installation height and appropriately loosen the spring that can be moved with a screwdriver, ensuring a movement distance of 2-4mm.
1.2.3 Under-tight Installation
There is a thin layer of scale on the planes of the rotating and stationary rings of the mechanical seal, which can be wiped off, but the surface has basically no wear. This may be caused by the spring losing its elasticity, poor assembly, or the axial movement of the motor. It is necessary to check the stability of the installation and the axial stability of the motor.
1.2.4 Impact of Water Quality
If the water quality is poor, containing small particles or the medium has a high content of hydrochloride, it may cause abrasive wear on the plane of the mechanical seal or result in phenomena such as grooves and ring grooves. Treatment methods include improving water pressure or medium conditions and replacing the mechanical seal.1.2.5 Dry Running Problem (Lack of Water)
This situation is more common in bottom valve-type installations where there is negative pressure at the inlet, air in the water inlet pipe, or air in the pump chamber. When the pump is started, the mechanical seal generates high temperature due to high-speed friction and cannot be cooled. Inspection reveals that the tension of the mechanical seal spring is normal, but the friction surface is scorched black, and the rubber is hard and cracked. The solution is to exhaust the air in the pipeline and pump chamber and replace the mechanical seal.1.2.6 Cavitation Phenomenon
It mainly occurs in hot water pumps. Since the medium is hot water, excessively high water temperature will generate steam. The gas in the pipeline enters the high part of the pump chamber and cannot be discharged, leading to dry running and failure of the mechanical seal due to dry friction. The solution is to install an automatic exhaust valve and replace the mechanical seal.