Installation and Operation Manual
1. Operating Parameters
1.1 Operating Conditions
2009 Mechanical Seal for  Reactor.jpg
  • Operating Pressure (Mechanical Seal): ≤ 0.4 MPa
  • Operating Pressure (Mechanical Seal with Balance/Barrier Tank): ≤ 0.6 MPa
  • Operating Temperature: ≤ 150℃
  • Shaft Peripheral Speed: ≤ 2 m/s (Rotational speed generally ≤ 300 rpm)
  • Applicable Media: Strongly corrosive gases and liquids, such as acids and alkalis.
    (Note: The pressure in the balance tank must be higher than the pressure in the reactor to prevent the leakage of strongly corrosive gases.)
  • Seal Lubricating Fluid: Supplied by the user (e.g., white oil, engine oil, purified water, or low-corrosive, harmless liquids such as water + ethylene glycol).
  • Dry Running Operation: Pressure ≤ 0.4 MPa, Temperature ≤ 130℃, Peripheral speed ≤ 0.8 m/s.
    (Note: The seal chamber must be purged with nitrogen gas—in/out flow or nitrogen blanketing—to prevent the leakage of strongly corrosive gases.)
1.2 Installation Conditions
  • Suitable for vertical reactors. The mechanical seal installation area on the glass-lined agitator shaft must be precision-ground.
  • Shaft Runout: Axial displacement ≤ 0.5 mm, Radial runout ≤ 0.15 mm.
  • Shaft Requirements: Surface roughness Ra ≤ 1.6; Diameter tolerance h7.
  • ⚠️ Important: The mechanical seal must be operated strictly according to the rotation direction specified by the agitator manufacturer!
1.3 Structural and Functional Features
  1. Balanced, double-end (with bearing), sanitary-grade mechanical seal with multi-directional rotation.
  2. Cartridge-type mechanical seal. Installers must strictly follow the installation procedure and properly control the axial displacement.
  3. Seal materials shall be selected based on customer requirements or the provided operating conditions.
  4. Cooling Methods: Jacket water cooling / Seal fluid lubrication and cooling; Nitrogen gas cooling is adopted during dry running operation.