Successfully Completes On-site Replacement of Model 2009 Sanitary Mechanical Seal for Pharmaceutical Reactor

Successfully Completes On-site Replacement of Model 2009 Sanitary Mechanical Seal for Pharmaceutical Reactor

2026-10-09
Zhejiang Jiemi is a professional manufacturer and service provider dedicated to the R&D, production and customized application of high-precision mechanical seals. The company focuses on sanitary-grade sealing products for pharmaceutical, chemical, food and other industries, and has accumulated rich on-site application experience in reactor, mixer and other process equipment sealing scenarios, providing reliable sealing solutions and professional technical support for industrial customers nationwide.

view detail
On‑Site Replacement & Field Application of Zhejiang Jiemi N4202‑D Mechanical Seals for Process Circulating Pumps in a State‑Owned Chemical Plant

On‑Site Replacement & Field Application of Zhejiang Jiemi N4202‑D Mechanical Seals for Process Circulating Pumps in a State‑Owned Chemical Plant

2026-09-16

Circulating pumps are critical rotating assets within the chemical plant. The original mechanical seals experienced persistent leakage issues due to the corrosive process media and continuous operating conditions. Frequent unplanned shutdowns for seal maintenance led to production losses and escalated maintenance costs for the facility. Consequently, the plant sought a more robust alternative mechanical sealing solution.

view detail
What is Mechanical Seal for Agitating Reactor ?2017W  Type Mechanical Seal for Agitating Reactor

What is Mechanical Seal for Agitating Reactor ?2017W Type Mechanical Seal for Agitating Reactor

2026-09-10

Jiemi Seal releases the 2017W hygienic cartridge‑type reactor mechanical seal. It is a balanced double seal without built‑in bearing for bidirectional rotation. Designed for food, pharmaceutical, chemical and metallurgical reactors, it supports jacket water cooling and seal‑fluid cooling. Its standard service reaches ≤0.4 MPa, ‑20~150 °C, linear velocity ≤2 m/s. Under extended conditions, it can run below 1.6 MPa at ‑40~150 °C for non‑particle highly‑corrosive fluids, excluding hydrofluoric acid. For pressure over 0.4 MPa or flammable‑explosive and toxic media, a balance tank is required; seal chamber pressure shall be kept 0.1‑0.2 MPa higher than process medium pressure.

view detail
Application Scenarios: JEMI SEAL for Industrial Filter-Wash-Dryers ("Three-in-One" Equipment)

Application Scenarios: JEMI SEAL for Industrial Filter-Wash-Dryers ("Three-in-One" Equipment)

2026-08-31
Zhejiang Jemi Seal specializes in the on-site production and service of high-performance mechanical seals designed specifically for industrial-grade Filter-Wash-Dryers (commonly known as "Three-in-One" equipment). Our sealing solutions are engineered to withstand the complex, multi-stage processes of filtration, washing, and drying within a single vessel.
In the pharmaceutical industry, "Three-in-One" dryers are critical for processing Active Pharmaceutical Ingredients (APIs) and intermediates. JEMI SEAL provides compliant solutions for these high-value, sterile powder processes, ensuring strict containment to prevent contamination and guarantee operator safety.
view detail
JIEMI SEAL’s Model 2007 & 2009 Mechanical Seals application case

JIEMI SEAL’s Model 2007 & 2009 Mechanical Seals application case

2026-08-19

The Model 2007 and Model 2009 mechanical seals have run continuously for up to 8,000 hours with zero leakage at the pharmaceutical production site.

view detail
What are the Agitator Mechanical Seal ? Installation Instructions for Model 2028 Agitator Mechanical Seal

What are the Agitator Mechanical Seal ? Installation Instructions for Model 2028 Agitator Mechanical Seal

2026-08-12

Abstract of Installation Instructions for Type 2028 Mechanical Seal

This abstract summarizes the standardized installation procedures for the 2028 cartridge agitator mechanical seal applied in pharmaceutical, fine chemical and biopharmaceutical industries with sterile working requirements.
Before installation, operators need to study the manual and drawings comprehensively, clean the seal assembly with alcohol and inspect component integrity, and keep the seal upright all the time during transportation and hoisting to protect friction pairs. Remove outer plugs and pipe fittings for safekeeping, and only coat medical petrolatum on the sleeve inner hole and flange O-rings instead of machine oil or grease to avoid seal failure. All port plugs shall only be detached in a sterile room and connected with valved pipelines right away.
During mounting, hoist the seal under the tank flange with perfect horizontal and vertical perpendicularity, fasten flange bolts uniformly to prevent O-ring damage. Lubricate the smooth and scratch-free agitator shaft with silicone oil, slide it slowly into the sleeve without jamming, assemble the top gland and flat key to ensure the shaft moves up and down flexibly. Finally, restore all disassembled spare parts and connect each interface with matched pipelines equipped with control valves.
Before trial operation, verify full assembly correctness and pipeline connectivity, activate the recommended sterile nitrogen cooling gas first, and start the stirring shaft and reciprocating lifting operation only under fault-free status.
view detail
What are the Mechanical Seal?TNNS Special Mechanical Seal Optimizes Reliability for Flue Gas Desulfurization Pump Service

What are the Mechanical Seal?TNNS Special Mechanical Seal Optimizes Reliability for Flue Gas Desulfurization Pump Service

2026-08-07

“Flue‑gas desulfurization pumps work under extremely demanding slurry conditions. Our TNNS mechanical seal is developed exactly for these tough working scenarios,” said the technical representative from JIEMI SEAL. “We focus on solving real‑site pain points, helping end‑users achieve longer seal service cycles and stable continuous operation of desulfurization systems.”

view detail
What are mechanical seals?  N4202 TYPE MECHANICAL SEAL INSTALLATION & OPERATING INSTRUCTIONS

What are mechanical seals? N4202 TYPE MECHANICAL SEAL INSTALLATION & OPERATING INSTRUCTIONS

2026-08-04

Assembly steps onto pump unit:

  1. Slide the mechanical seal over the pump shaft. Keep the pump shaft perpendicular to seal flange and concentric with sleeve, then secure the pump shaft.
  2. Fit a gasket between seal flange and equipment shoulder, then fasten with Screw 1.
  3. Complete assembly of all other pump parts.
  4. Tighten Round Nut 2 to lock the sleeve onto the agitator shaft.
  5. Rotate the shaft manually or by dedicated wrench for multiple revolutions. Smooth rotation without abnormal friction or obstruction is required.
view detail
What are  the Mechanical Seal for Special For General Pumps? N5001K Mechanical Seal for FGD & Coal Washing Slurry Pumps

What are the Mechanical Seal for Special For General Pumps? N5001K Mechanical Seal for FGD & Coal Washing Slurry Pumps

2026-07-30

This new model provides a cost-effective localized alternative to imported seals for power, metallurgy and coal chemical industries. JIEMI SEAL keeps developing interchangeable mechanical seals to lower customers’ spare parts and maintenance expenses.

view detail