Leave Your Message
Double mechanical seal for 207 type kettle
Reactor Mechanical Seal

Double mechanical seal for 207 type kettle

The Type 207 mechanical seal is a balanced double-seal unit designed for bidirectional operation in various industrial mixing applications. It provides direct replacement compatibility with Type 205 and 206 seals while offering enhanced pressure and temperature capabilities. 

    Structural characteristics

    ●Double-end design, multi-spring balanced structure, the medium end is unbalanced and the atmosphere end is balanced (UB type).

    ●Adopting transmission sleeve/lug transmission, the spring pressure is evenly distributed, the axial size is compact, and the compensation component is pre-assembled as a whole, which is convenient for installation.

    ●A sealing liquid circulation system (such as an isolation liquid tank) is required. The sealing liquid pressure should be 0.05~0.2MPa higher than the medium pressure to achieve two-way sealing protection.

    Working parameters

    ●Pressure: Sealing chamber pressure ≤1.6MPa, medium pressure ≤1.5MPa (after sealing hydraulic pressure differential compensation)

    ●Temperature: -40℃~250℃ (high temperature working conditions require a cooling system)

    ●Linear speed: ≤20m/s

    ●Speed: ≤500r/min

    ●Shaft diameter: φ30mm~φ160mm

    Applicable media

    Flammable, explosive, and toxic media (such as organic solvents and hydrocarbons), highly corrosive media (acids, alkalis, and salt solutions), chemical liquids containing particles (particle content ≤ 25%), and clean media with "zero tolerance" for leakage (such as the pharmaceutical and food industries).

    Application Areas

    ●Reactor: Enamel reactor, stainless steel high-pressure reactor, stirring shaft seal of stirring kettle.

    ●Chemical equipment: vertical rotating shaft seals of distillation towers, fermentation tanks, and storage tanks.

    ●Industry coverage: Strict sealing scenarios in petrochemical, pharmaceutical, food, environmental protection, metallurgy and other fields.

    Special Instructions

    ●During installation, the verticality between the kettle flange and the shaft must be strictly checked (≤0.1mm), and the surface roughness of the shaft diameter must be Ra≤3.2μm.

    ●The sealing liquid must be compatible with the medium. For granular medium working conditions, it is recommended to use silicon carbide to silicon carbide friction pairs to enhance wear resistance.

    ●When the pressure is greater than 0.4MPa, a pressure balance tank must be installed. When the temperature is greater than 180℃, a cooling water tank must be added and the installation height must be increased (approximately 80mm).